Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
1.
Braz Oral Res ; 38: e024, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38597544

RESUMO

This study aimed to identify and characterize the antimicrobial susceptibility profile of bacteria found in primary endodontic infections in the teeth of patients treated at the Dental Clinic of the University of Ribeirão Preto, São Paulo, Brazil. From September to December 2019, samples were obtained from 21 patients with primary endodontic infections. The collections were carried out in triplicate using paper cones placed close to the total length of the root canal. Bacterial isolation was performed in Brain Heart Infusion agar, Blood agar, and other selective culture media cultured at 37°C for up to 48 h under aerobiosis and microaerophilic conditions. The bacterial species were identified using the Vitek 2 automated system. The disk diffusion method on agar Müeller-Hinton was used to assess antimicrobial susceptibility with the recommended antimicrobials for each identified bacterial species. A total of 49 antibiotics were evaluated. Fifteen of the 21 samples collected showed bacterial growth, and 17 bacterial isolates were found. There were 10 different bacterial species identified: Enterococcus faecalis (four isolates), Streptococcus mitis/oralis (three isolates), Streptococcus anginosus (three isolates) being the most common, followed by Staphylococcus epidermidis, Enterococcus faecium, Streptococcus constellatus, Streptococcus alactolyticus, Enterobacter cloacae, Klebsiella variicola, and Providencia rettgeri (one isolate of each species). The analysis demonstrated significant susceptibility to most of the tested antibiotics. However, some Enterococcus isolates resisted the antibiotic's erythromycin, ciprofloxacin, and tetracycline. A Staphylococcus epidermidis isolate was characterized as multidrug-resistant. Five Streptococcus isolates were non-susceptible to all antibiotics tested.


Assuntos
Anti-Infecciosos , Enterococcus faecium , Humanos , Ágar , Testes de Sensibilidade Microbiana , Brasil , Antibacterianos/farmacologia , Meios de Cultura
2.
Odontology ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514512

RESUMO

To evaluate the impact on the quality of filling with of low-fusion and conventional gutta-percha cones. Thirty-six maxillary canines were prepared and divided into three groups: I-conventional cone with Downpack at 200 °C at 4 mm from the WL; II-low-fusion cone with Downpack at 100 °C up to 4 mm from the WL; III-low-fusion cone with Downpack at 100 °C up to 7 mm from the WL. Temperature variations were measured in thirds on the external surface of the root. The bond strength was evaluated using the push-out test. The adhesive interface was analyzed by scanning electron microscopy. The bond strength and the temperature variation data were analyzed using analysis of variance and the failure type using the chi-square test. The low-fusion cone group with 7 mm Downpack showed higher bond strength (4.2 ± 2.7) compared with conventional cones (2.8 ± 1.6) and low-fusion cones with 4 mm Downpack (2.9 ± 1.6) (p < 0.05), with occurrence of a higher number of adhesive failures to the filling material and mixed failures. Relative to temperature variation, there was less temperature change in the apical third, in the low-fusion cone with Downpack 7 mm (1.0 ± 1.0) (p < 0.05). The use of low-fusion cones allowed the continuous wave condensation technique to be performed at a lower depth of Downpack at 100 °C at 7 mm, with less heating in the apical third, without compromising the quality of filling. Using gutta-percha cones with low fusion, which permits a lower condensation temperature and reduced Downpack depth, maintains the quality of filling, in order to minimize possible damage to the periapical tissues.

3.
J Mech Behav Biomed Mater ; 151: 106354, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38232670

RESUMO

The aim of this study was to evaluate the effects of supplementing toothpastes containing 1100 ppm F with micrometric or nanometric [beta]-calcium glycerophosphate (ß-CaGPm/ß-CaGPn) on artificial enamel demineralization, using a pH cycling model. Bovine enamel blocks (4 mm × 4 mm, n = 120) selected using initial surface hardness were randomly allocated to ten toothpaste groups (n = 12): without fluoride or ß-CaGPm or ß-CaGPn (Negative control), 1100 ppm F (1100 F), and 1100 ppm F plus 0.125%, 0.25%, 0.5%, and 1.0% of ß-CaGPm or ß-CaGPn. Blocks were treated two times per day with toothpaste slurry and subjected to five pH cycles (demineralizing and remineralizing solutions) at 37 °C. The final surface hardness, percentage of surface hardness loss (%SH), cross-sectional hardness (ΔKHN), and profile analysis and lesion depth subsurface were analysed using polarized light microscopy (PLM). Fluoride (F), calcium (Ca), and phosphorus (P) concentrations were also measured. Data were analysed using ANOVA and Student-Newman-Keuls tests ([alpha] = 0.001). Blocks treated with 1100 F toothpaste containing 0.5%ß-CaGPm or 0.25%ß-CaGPn showed with reduced %SH values when compared with those treated with 1100 F alone (p < 0.001). Reduced lesion depths (ΔKHN and PLM) were observed for the slurry made up of 1100 F and 0.25%ß-CaGPn (p < 0.001). The addition of ß-CaGPm and ß-CaGPn did not influence the enamel F concentration, with the 1100 F/0.25%ß-CaGPn group exhibiting the highest Ca and P enamel concentrations (p < 0.001). Based on the findings of this in vitro study, we can conclude that the fluoride toothpaste produced a superior effect when combined at an appropriate ß-CaGP molar ratio. This effect was achieved with a lower proportion of ß-CaGP in the form of nanometric particles.


Assuntos
Fluoretos , Desmineralização do Dente , Humanos , Animais , Bovinos , Fluoretos/farmacologia , Fluoretos/análise , Cremes Dentais/farmacologia , Cálcio , Glicerofosfatos , Estudos Transversais , Desmineralização do Dente/prevenção & controle , Dureza , Suplementos Nutricionais , Concentração de Íons de Hidrogênio
4.
J Mech Behav Biomed Mater ; 151: 106400, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262184

RESUMO

AIM: To mensure the physicochemical properties of three ceramic cement endodontic sealers AH Plus Bioceramic, Bio-C Sealer and Bio-C Sealer Ion+ with an epoxy resin sealer, AH Plus. MATERIAL AND METHODS: These properties were measured: hardening time (HT), dimensional change (DC), solubility (SL), flow (FL) and radiopacity (RD). The distilled water obtained from the SL test was analyzed with atomic absorption spectrometry. A sample calculation was made considering n = 5 repetitions for each experimental sealer evaluated. Statistical analysis was performed using one-way ANOVA and post hoc Tukey tests (p < 0.05). RESULTS: For the HT, AH Plus (484 ± 2.76 min) and AH Plus Bioceramic (424 ± 1.23 min) set more slowly than of Bio-C Sealer (370 ± 4.50 min) and Bio-C Sealer Ion+ (380 ± 1.42 min) (p < 0.05). AH Plus Bioceramic (12.56 ± 2.71 %) was more soluble than Bio-C Sealer (6.69 ± 1.67 %), Bio-C Sealer Ion+ (5.67 ± 2.16 %) and AH Plus (0.15 ± 0.01 %) (p < 0.05). AH Plus (0.03 ± 0.01 %) had slight expansion while the cement-based sealers had shrinkage: AH Plus Bioceramic (-1.60 ± 0.63 %) and Bio-C Sealer (-1.38 ± 0.69 %), Bio-C Sealer Ion+ (-5.19 ± 1.23 %) (p < 0.05). Bio-C Sealer Ion+ (59.80 ± 0.86 mm) and Bio-C Sealer (58.60 ± 0.98 mm) had the highest flow compared with AH Plus (56.90 ± 0.56 mm) and AH Plus Bioceramic (49.50 ± 0.63 mm) (p < 0.05). AH Plus (9.17 ± 0.06 mmAl) and AH Plus Bioceramic (8.27 ± 0.84 mmAl) showed radiopacity values when compared with those of Bio-C Sealer (4.90 ± 0.08 mmAl) and Bio-C Sealer Ion+ (4.14 ± 0.05 mmAl) (p > 0.05). CONCLUSION: Ion release is inhered to these cement-based sealers and this result in calcium ion release.


Assuntos
Cálcio , Materiais Restauradores do Canal Radicular , Cálcio/química , Materiais Restauradores do Canal Radicular/química , Compostos de Cálcio/química , Resinas Epóxi/química , Silicatos/química , Teste de Materiais
5.
Braz Oral Res ; 37: e096, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38055514

RESUMO

The survival of endodontically treated teeth depends on the remaining tooth structure. The aim of this study was to evaluate the impact of different access cavities on root canal preparation, restorative protocol, and fracture resistance of endodontically treated teeth. Fifty-six mandibular molars were divided into control (n=8) and experimental (n=16) groups according to access cavity: Traditional, Conservative, and Truss; and redistributed (n=8) according to instrumentation protocols: Reciproc Blue and R-motion. After, teeth were scanned in micro-CT and then filled and redistributed according to composite resin restoration (n=8): Filtek One BulkFill and Filtek Z350. A new micro-CT scan was performed to analyze the restorative material. Then, samples were submitted to fracture resistance testing and the failure pattern was determined. Data were analyzed using paired T-test, ANOVA, Tukey, and chi-square tests (α=0.05). In Truss, R-Motion promoted less transportation in different thirds of root canals. Higher percentages of voids (5.05%) and filling material (11.7%) were observed in Truss. Fracture resistance values were higher for the control group, followed by Truss, Conservative, and Traditional. The predominant failure pattern was type-II. In Truss, reciprocating instruments with smaller taper showed less canal transportation. Also, Truss provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material. Thus, in Truss, reciprocating files with smaller taper showed less canal transportation, and these cavities provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material.


Assuntos
Cárie Dentária , Materiais Restauradores do Canal Radicular , Dente não Vital , Humanos , Preparo de Canal Radicular/métodos , Dente Molar , Microtomografia por Raio-X , Cavidade Pulpar
6.
Odontology ; 2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37803215

RESUMO

This study evaluated the feasibility of an automated method to delimit the required area to quantitatively analyze root filling voids and gaps from cross-sectional confocal laser scanning microscopy (CLSM) images. Root canals of maxillary canines were prepared with rotary instruments and filled by lateral compaction technique using gutta-percha and AH Plus sealer. The roots were stored (100% humidity, 37 °C) for a period of 24 h and then transversally sectioned to obtain 2-mm-thick slices from the apical and middle thirds. The areas corresponding to filling materials, gaps, and voids were manually delimited or automatically demarked by ImageJ software after converting the images to the RGB color system. Based on manual and automatic delimitations, the percentages of voids and gaps were calculated. Data of voids and gaps between middle and apical thirds were individually compared by paired t-test. Pearson`s correlation test was used to assess the correlation of data between the methods. Irrespective of the method of area delimitation, no difference was observed between the root thirds for both voids and gaps, while the p-values calculated for each method were similar. Almost perfect correlations between the methods were observed for both outcomes. The proposed method to automatically delimit the areas corresponding to filling material, voids, and gaps appears to be a valid method to facilitate the quantitative analysis of defects in root canal fillings using topographic CSLM images.

7.
J Dent ; 138: 104719, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37741503

RESUMO

OBJECTIVES: This in situ study aimed to assess the remineralizing effect of a fluoride toothpaste supplemented with ß-calcium glycerophosphate in both micro (ß-CaGPm) and nano-sized forms (ß-CaGPn). METHODS: This blind and cross-over study was performed in 4 phases, each spanning 3 days. Twelve volunteers utilized palatal appliances containing four bovine enamel blocks with artificial caries lesions. Volunteers were randomly assigned to the following treatment groups: Placebo (no F-ß-CaGPm-ß-CaGPn); 1100 ppm F alone (1100F); 1100F plus 0.5% micrometric ß-CaGP (1100F-0.5%ß-CaGPm); and 1100F plus 0.25%nano-sized ß-CaGP (1100F-0.25%ß-CaGPn). Participants were instructed to brush their natural teeth with the palatal appliances in the mouth for 1 min (3 times/day), ensuring that the enamel blocks were exposed to the natural toothpaste slurries. Following each phase, evaluations were conducted to determine the percentage of surface hardness recovery (%SHR), integrated recovery of subsurface hardness (ΔIHR), profile subsurface lesion through polarized light microscopy (PLM), as well as fluoride (F), calcium (Ca), and phosphorus (P) concentrations within the enamel. Data were analyzed by ANOVA and Student-Newman-Keuls test (p < 0.001). RESULTS: Treatment with 1100F-0.25%ß-CaGPn resulted in %SHR ∼69 % and ∼40 % higher when compared to 1100F and 1100F-0.5%ß-CaGPm (p < 0.001). The reduction in lesion body (ΔIHR; PLM) was ∼40 % higher with 1100F-0.25%ß-CaGPn (p < 0.001) compared to 1100F. The addition of ß-CaGPm and ß-CaGPn did not influence enamel F concentration (p > 0.001). Treatment with 1100F-0.25%ß-CaGPn led to an increase in the concentration of Ca and P in the enamel (p < 0.001). CONCLUSION: The addition of 0.25%ß-CaGPn into 1100F formulation increased the bioavailability of calcium and phosphate, promoting a higher remineralizing effect. CLINICAL SIGNIFICANCE: Toothpaste containing 1100F-0.25%ß-CaGPn showed a potential of higher remineralization to 1100 ppm F and 1100 ppm F micrometric ß-CaGP could be a strategy for patients at caries activity.


Assuntos
Fluoretos , Cremes Dentais , Animais , Bovinos , Humanos , Cálcio/farmacologia , Cariostáticos/farmacologia , Estudos Cross-Over , Esmalte Dentário , Fluoretos/farmacologia , Glicerofosfatos/farmacologia , Dureza , Remineralização Dentária/métodos , Cremes Dentais/farmacologia , Cremes Dentais/uso terapêutico
8.
Dent Mater J ; 42(4): 532-541, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37225458

RESUMO

To evaluate the push-out bond strength of the adjustable fiberglass post system to dentin. Twenty maxillary canine roots were endodontically treated and divided into two groups (n=10): conventional fiberglass posts (CFPs) and with single adjustable post (SAP) system. Two slices of each third were subjected to the push-out and failure pattern test and the most apical slice was subjected to analysis of the adhesive interface by scanning electron microscopy (SEM). Data were analyzed by the three-way analysis of variance, Tukey, and Friedman tests, and linear regression (α=0.05). The results showed higher push-out bond strength in the initial time interval for SAP (10.3±5.3, p<0.01). After 6 months, there was reduction in push-out bond strength for both (p<0.001). A higher percentage of adhesive and cohesive failures to dentin. After 6 months areas of maladaptation were noted (p=0.000). The SAP is completed to the promissory root canal in relation to alternative CFP.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Colagem Dentária/métodos , Cavidade Pulpar , Vidro , Dentina , Teste de Materiais , Cimentos de Resina/química
9.
Aust Endod J ; 49(1): 130-139, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35649116

RESUMO

Shaping ability evaluation of taper ./01 instruments in large root canals, by microcomputed tomography (micro-CT) and scanning electron microscopy (SEM). Maxillary central incisors with large diameter root canals were divided into two groups (n = 10): XP-Endo Shaper (FKG-Dentaire, Switzerland) and manual instrumentation (FKG-Dentaire). Two- and three-dimensional parameters from cervical to apical root thirds were evaluated by micro-CT. Apical stop was evaluated by SEM images. Data were analysed by ANOVA and Tukey tests (α = 5%). XP-Endo Shaper allowed a regular biomechanical preparation with less dentinal wear compared with manual instrumentation, which showed excessive wear of the thin root canal walls (p < 0.05). Roundness and SMI showed similarity between both protocols (p > 0.05). XP-Endo Shaper SEM showed a regular and well-defined shape of the apical foramen suggesting the formation of the apical stop. Reduced diameter and taper instruments promoted a conservative wear and a well-defined apical stop formation in large root canals.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Preparo de Canal Radicular/métodos , Tratamento do Canal Radicular , Ápice Dentário/diagnóstico por imagem
10.
J Photochem Photobiol B ; 238: 112612, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36459910

RESUMO

Photobiomodulation therapy (PTB) is a therapeutic possibility for temporomandibular disorders (TMD), but its effectiveness and protocols for use remain controversial. This study is a RCT that compared the effectiveness of PTB on pain points of the masticatory muscles and TMJs, located through palpation versus application of pre-established points in women with painful TMD, diagnosis by DC/TMD (Diagnostic Criteria for Temporomandibular Disorders - Brazilian Portuguese version). Therefore, a total sample of 54 women, aged between 18 and 60 years, was investigated. Volunteers were randomly randomized and PTB was applied in four different groups with a dose of 4 J and 6 J divided into pre-established application points (PE - G1) and pain points (PD - G2) - Groups 4PE, 4PD, 6PE and 6PD. Four laser applications were performed with a wavelength of 780 nm, one session per week, totaling one month of therapy. The following assessments were performed: DC/TMD, Brief Pain Inventory (BPI), McGill Questionnaire - Short Version (SF-MPQ) and Pain Intensity, Visual Analogue Scale (VAS). Friedman's test was used for within-group comparisons, while the Mann-Whitney test was used for between-group comparisons (p < 0.05). According to the results, laser application on pain points (G2) was more effective. McGill's results showed that regardless of dose, the pain point application group had better outcomes (p = 0.004). Pain intensity evaluation (last days) also showed that application at the pain points was more effective regardless of dose (p = 0.0002). Medians and interquartile deviations showed overall that PTB was more effective at pain points, with a trend towards better outcomes at the 6 J dose. Therefore, it can be concluded that in women with chronic painful TMD, the application of PTB at pain points is more effective than the application at pre-established points. Therefore, individualized PTB protocols are proposed, based on examination palpation of the masticatory structures.


Assuntos
Dor Crônica , Terapia com Luz de Baixa Intensidade , Transtornos da Articulação Temporomandibular , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Dor Crônica/radioterapia , Transtornos da Articulação Temporomandibular/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Medição da Dor , Músculos da Mastigação
11.
Braz. oral res. (Online) ; 37: e096, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520524

RESUMO

Abstract The survival of endodontically treated teeth depends on the remaining tooth structure. The aim of this study was to evaluate the impact of different access cavities on root canal preparation, restorative protocol, and fracture resistance of endodontically treated teeth. Fifty-six mandibular molars were divided into control (n=8) and experimental (n=16) groups according to access cavity: Traditional, Conservative, and Truss; and redistributed (n=8) according to instrumentation protocols: Reciproc Blue and R-motion. After, teeth were scanned in micro-CT and then filled and redistributed according to composite resin restoration (n=8): Filtek One BulkFill and Filtek Z350. A new micro-CT scan was performed to analyze the restorative material. Then, samples were submitted to fracture resistance testing and the failure pattern was determined. Data were analyzed using paired T-test, ANOVA, Tukey, and chi-square tests (α=0.05). In Truss, R-Motion promoted less transportation in different thirds of root canals. Higher percentages of voids (5.05%) and filling material (11.7%) were observed in Truss. Fracture resistance values were higher for the control group, followed by Truss, Conservative, and Traditional. The predominant failure pattern was type-II. In Truss, reciprocating instruments with smaller taper showed less canal transportation. Also, Truss provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material. Thus, in Truss, reciprocating files with smaller taper showed less canal transportation, and these cavities provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material.

12.
J Mech Behav Biomed Mater ; 135: 105486, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36182677

RESUMO

Chemical composition of temporary cements interferes in the bond strength and quality of the bond interface of glass fiber posts to root dentin. The aim of the present study was to evaluate the influence of different temporary cements on the bond strength of fiberglass posts and resin cement. Thirty-two maxillary central incisor roots were standardized at 15 mm length. The root canals were prepared with Reciproc R50 and filled with a R50 single cone and AH Plus. Ten mm of filling material was removed with a heated Schilder condenser, leaving 5 mm of apical filling material. The roots were randomly distributed into 4 groups (n = 8). In the control group, the root canal was prepared with a standard drill according to the post diameter (DC #1, FGM, Joinville, Brazil), irrigated with 5 mL of distilled water and immediately received the fiberglass post cemented with self-adhesive resin cement. For the other groups, cores were made with temporary intraradicular retainers cemented with different temporary cements: methacrylate-based resin (Bifix Temp - Voco), calcium hydroxide-based (Provicol - Voco) and zinc oxide-based - eugenol-free (Relyx Temp NE - 3M). After 7 days, mechanical removal of the temporary retainers, preparation, irrigation of the root canal and cementation of the fiberglass post were performed, following the same protocol that had been performed in the control group. The roots were sectioned to obtain 3 slices per root third. The most cervical section of each third was used for the push-out test and failure pattern analysis, while the most apical section was subjected to analysis of the adhesive interface by scanning electron microscopy (SEM). The BS data were compared between groups using the two-way ANOVA and Tukey post-test. The failure pattern results were expressed in percentage and compared between groups using the chi-square test and the material adaptation data at the bond interface were evaluated using the Kruskal-Wallis and Dwass-Steel-Critchlow-Fligner tests. The results showed higher BS in the cervical third, with a higher value in the control group (10.8 ± 0.94) and Bifix Temp group (9.78 ± 0.71), with no statistically significant difference between these groups (P > .05). The middle and apical thirds showed no statistically significant difference (P > .05). As regards the type of failure, a higher percentage of mixed adhesive failures was observed for all groups. Analysis of the adhesive interface by SEM showed that the temporary cement Bifix Temp showed greater adaptation at the bond interface. It was concluded that the methacrylate-based resin temporary cement showed the highest bond strength values and best adaptation to root dentin than the zinc oxide-based and calcium hydroxide-based temporary cements.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Óxido de Zinco , Hidróxido de Cálcio , Cimentação/métodos , Análise do Estresse Dentário , Dentina , Vidro/química , Hidroxibenzoatos , Teste de Materiais , Metacrilatos , Nitrofuranos , Cimentos de Resina/química , Aço , Água
13.
Int Endod J ; 55(1): 124-136, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34687053

RESUMO

AIM: To evaluate the shaping ability of several heat-treated nickel-titanium systems used to prepare root canals with moderate and severe curvature, in extracted mandibular molars, by micro-computed tomography, considering their variation in kinematics and design. METHODOLOGY: Curved-mesial roots of mandibular molars were randomly selected and assigned into 4 balanced experimental groups (n = 10), established by determining homogeneous 3D parameters of volume and surface area: R-Motion (RM) size 30, 0.04 taper (RM; FKG Dentaire), Reciproc Blue (RCB) size 25, 0.08 taper (RCB; VDW GmbH), HyFlex CM (HFX) size 30, 0.04 taper (HFX; Coltène Whaledent) and XP-endo Shaper size (XPS) 30, 0.01 taper (XPS; FKG Dentaire). The volume of irrigation was established at 10 ml of 2.5% NaOCl. Throughout the entire root canal preparation procedures, the samples were fixed in a vice submerged in a container with water monitored at 37°C. Dimensional cross-sectional measures of area, perimeter, roundness, major/minor diameters and 3-dimensional (volume, surface area, structure model index - SMI) parameters as well as the smallest dentine thickness along the cervical and middle root thirds were evaluated by micro-CT. Data were analysed using analysis of variance and post hoc Tukey tests (α = 5%). RESULTS: Reciproc Blue and XPS had significantly greater mean increases in cross-sectional area measurements, only in the middle third, when compared with RM and HFX (p < .05). RM, RCB and XPS had a similar increase in measurements of length and width of perimeter (p > .05), and HFX had significantly lower mean increases in perimeter values only when compared with XPS (p < .05). RCB and XPS had significantly greater mean increases in volume when compared with RM and HFX (p < .05). RM had a significantly lower difference in SMI after preparation, compared with RCB, HFX and XPS (p < .05). The smallest dentine thickness was observed after the use of RCB (p < .05), in the danger and safety zones. CONCLUSIONS: XP-endo Shaper and RM had a shaping ability similar to that of instruments with larger tapers, achieved with less dentine removal in danger and safe zones in curved-mesial canals of extracted molar teeth treated on a laboratory benchtop.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Níquel , Titânio , Microtomografia por Raio-X
14.
Lasers Med Sci ; 37(1): 573-580, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33844114

RESUMO

This study evaluated the influence of photobiomodulation (PBM) using low-level laser therapy (PBM/LLLT) or light-emitting diode (PBM/LED) therapy on peri-implant tissue healing. A laboratory model was used to assess the adhesion and metabolism of osteoblasts (SaOs-2), human gingival fibroblasts (HGF), and normal oral keratinocytes (NOK) seeded on a titanium (Ti) surface. After seeding the cells on disks of Ti placed in wells of 24-well plates, three irradiations were performed every 24 h at energy density of 3 J/cm2. For PBM/LLLT, a LaserTABLE device was used with a wavelength of 780 nm and 25 mW, while for PBM/LED irradiation, a LEDTABLE device was used at 810 nm, 20 mW, at a density of 3 J/cm2. After irradiations, the number of cells (NC) attached and spread on the Ti surface, cell viability (CV), total protein (TP), and collagen (Col) synthesis were assessed. Alkaline phosphate activity (ALP) was evaluated only for SaOs-2. Data were submitted to ANOVA complemented by Turkey statistical tests at a 5% significance level. PBM significantly increased adherence of NOK to the Ti surface, while no significant effect was observed for SaOs-2 and HGF. PBM positively affected CV, as well as Col and TP synthesis, in distinct patterns according to the cell line. Increased ALP activity was observed only in those cells exposed to PBM/LLLT. Considering cell specificity, this investigation reports that photobiomodulation with low-power laser and LED at determined parameters enhances cellular functions related to peri-implant tissue healing in a laboratory model.


Assuntos
Terapia com Luz de Baixa Intensidade , Proliferação de Células , Gengiva , Humanos , Osseointegração , Osteoblastos
15.
Braz Dent J ; 32(5): 12-22, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34877974

RESUMO

The aim of this study was to evaluate the influence of different instruments and mechanisms of agitation of the irrigating solution on the penetration by confocal laser scanning microscopy (CLSM), and the bond strength (BS) of the filling material to the dentin by push-out test. Human premolars were distributed in two experimental groups (n=30), according to the instrumentation system: ProTaper Next (PN) or XP-endo Shaper (XS) and three irrigation protocol (n=10): NaviTip (Nv), XP-endo Finisher (XF), passive ultrasonic irrigation/ XP-endo Finisher (PUIXF). The 2.5% NaOCl and 17% EDTA were the irrigating solutions used. The filling was performed using a lateral condensation technique, with AH Plus added to 0.1% rodhamine B. The roots were sectioned, obtaining 2 slices for each third of the root. The first slice was submitted to the sealer penetration analysis and the push-out test. The second slice was submitted to qualitative analysis (SEM) of the union interface. For the penetration (%) Tukey showed that PNXF (82.38±13.48), PNPUIXF (82.48± 12.02), XSXF (82.24±11.28) and XSPUIXP (86.23±10.45) presented the highest values, different (p<0.05) from PNNv (68.29±15.12) and XSNv (71.41±16.50). The BS (MPa) test evidenced that in the cervical third, PNPF (4.92±1.04) and XPSPF (5.03±0.70) obtained the highest values differing from the others groups (p<0.05). CSLM and SEM showed greater penetration of the sealer on the entire length of the root canal when the irrigation solution was stirred. In conclusion that the association PUI and XP-endo Finisher favored the penetration and bond strength of the filling material to the root dentin.


Assuntos
Colagem Dentária , Materiais Restauradores do Canal Radicular , Cavidade Pulpar , Dentina , Resinas Epóxi , Guta-Percha , Humanos , Teste de Materiais , Irrigantes do Canal Radicular , Preparo de Canal Radicular
16.
Braz Oral Res ; 35: e117, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34816905

RESUMO

This study evaluated by the efficacy of rotary and reciprocating systems to remove filling material by micro-CT. Sixty human canines were instrumented up to F3 by ProTaper Universal system and filled with AH Plus/ gutta-percha. Specimens were submitted to 1,200 thermal cycles, scanned by microCT SkyScan 1176 and randomly distributed in groups according to the filling material removal protocol (n = 10): ProTaper Universal, ProTaper Universal/xylol, ProTaper Next, ProTaper Next/xylol, Reciproc and Reciproc/xylol. After filling removal, specimens were analyzed by microCT to separately verify the presence of gutta-percha and sealer remnants. The data (mm3) were analyzed by two way ANOVA and Tukey´s test (5%). For the remaining gutta-percha, the use of xylol provided the highest values for Reciproc (7.60 ± 0.73), which was statistically different from the other groups (p < 0.05) that presented lower values and were statistically similar to each other (p > 0.05). For the remaining sealer, xylol provided the highest values (21.25 ± 6.94) different (p < 0.05) from the use of instruments alone (11.47 ± 9.45). ProTaper Next presented the lowest values (8.16 ± 1.37) for the remaining sealer, different (p < 0.05) from that of Reciproc (24.67 ± 6.32). The qualitative analysis revealed that all groups presented some remaining root filling material, with the highest volumes presented by Reciproc and Reciproc/xylol. In conclusion the rotary systems provided greater removal of filling material regardless of the use of xylol. The use of xylol negatively interfered with the action of the reciprocating system in the removal of the gutta-percha and sealer.


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Guta-Percha , Humanos , Retratamento , Preparo de Canal Radicular , Solventes , Microtomografia por Raio-X
17.
Braz. dent. j ; 32(5): 12-22, Sept.-Oct. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1350296

RESUMO

Abstract The aim of this study was to evaluate the influence of different instruments and mechanisms of agitation of the irrigating solution on the penetration by confocal laser scanning microscopy (CLSM), and the bond strength (BS) of the filling material to the dentin by push-out test. Human premolars were distributed in two experimental groups (n=30), according to the instrumentation system: ProTaper Next (PN) or XP-endo Shaper (XS) and three irrigation protocol (n=10): NaviTip (Nv), XP-endo Finisher (XF), passive ultrasonic irrigation/ XP-endo Finisher (PUIXF). The 2.5% NaOCl and 17% EDTA were the irrigating solutions used. The filling was performed using a lateral condensation technique, with AH Plus added to 0.1% rodhamine B. The roots were sectioned, obtaining 2 slices for each third of the root. The first slice was submitted to the sealer penetration analysis and the push-out test. The second slice was submitted to qualitative analysis (SEM) of the union interface. For the penetration (%) Tukey showed that PNXF (82.38±13.48), PNPUIXF (82.48± 12.02), XSXF (82.24±11.28) and XSPUIXP (86.23±10.45) presented the highest values, different (p<0.05) from PNNv (68.29±15.12) and XSNv (71.41±16.50). The BS (MPa) test evidenced that in the cervical third, PNPF (4.92±1.04) and XPSPF (5.03±0.70) obtained the highest values differing from the others groups (p<0.05). CSLM and SEM showed greater penetration of the sealer on the entire length of the root canal when the irrigation solution was stirred. In conclusion that the association PUI and XP-endo Finisher favored the penetration and bond strength of the filling material to the root dentin.


Resumo O objetivo neste estudo foi avaliar a influência de diferentes instrumentos e mecanismos de agitação da solução irrigadora na penetração e resistência de união (RU) do AH Plus à dentina. Pré molares humanos foram distribuídos em dois grupos experimentais (n=30), de acordo com o sistema de instrumentação: ProTaper Next (PN) ou XP-endo Shaper (XS) e de acordo com três protocolos de irrigação (n=10): NaviTip (Nv), XP-endo Finisher (XF), passive ultrasonic irrigation/ XP-endo Finisher (PUIXF). A irrigação do canal radicular foi realizada com NaOCl 2,5% e EDTA 17%. A obturação foi realizada por meio da técnica da condensação lateral, com AH Plus acrescido de rodhamina B 0,1%. As raízes foram seccionadas, obtendo-se 2 slices de 2,0 mm para cada terço radicular. O primeiro slice foi submetido a análise da penetração do cimento e ao teste de push-out e o segundo slice submetido a MEV para análise da interface de união. Para penetração (%) Tukey evidenciou que PNXF (82,38±13,48), PNPUIXF (82,48±12,02), XSXF (82,24±11,28) e XSPUIXF (86,23±10,45) apresentaram os maiores valores, diferentes (p<0,05) de PNC (68,29±15,12) e XPSC (71,41±16,50). Na RU (MPa) foi evidenciado que PNPF (4,92±1,04) e XPSPF (5,03±0,70), no terço cervical, obtiveram os maiores valores diferentes dos demais (p<0,05). MCVL e MEV evidenciaram maior penetração do cimento em toda extensão da parede do canal radicular inclusive nas regiões polares, quando foi realizada a agitação da solução irrigadora. Concluiu-se que a associação PUI e XP-endo Finisher favoreceu a penetração e resistência de união do material obturador à dentina radicular.

18.
Clin Oral Investig ; 25(9): 5505-5512, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33655437

RESUMO

OBJECTIVES: This study aimed to evaluate the effects of different shaping protocols on the root canal geometry and remaining dentin thickness of mandibular premolars with radicular grooves (RG) and two canals by means of micro-CT. MATERIALS AND METHODS: Mandibular premolars with RG and two canals were matched based on their similar morphological dimensions and assigned to 2 experimental groups according to the canal preparation (n=8): XP-endo Shaper (XPS) and ProTaper Next (PTN) systems. Before and after preparation, morphometric measurements of the volume, surface area, structure model index, area, perimeter, roundness, major and minor diameters, as well as untouched canal walls, canal transportation, and dentin wall thickness were evaluated. Data were statistically compared within and between groups using the independent sample t test (α=5%). RESULTS: XPS revealed less changes in volume, surface area, area, perimeter, and major and minor diameters (P<0.05). There was no significant difference in structure model index (SMI), roundness, and percentage of untouched canal walls between groups (P>0.05). XPS resulted in less apical canal transportation and a higher remaining dentin thickness toward the RG compared to PTN in lingual canals (P<0.05). CONCLUSIONS: XPS revealed fewer changes in root canal geometry as well as lower transportation and a greater remaining dentin thickness in the lingual canals toward the RG compared to PTN. CLINICAL RELEVANCE: Internal and external anatomical characteristics of mandibular premolars might have an influence on biomechanical preparation. Considering the risk of perforation, the canal preparation using XPS appears to be more conservative compared to PTN.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Dente Pré-Molar/diagnóstico por imagem , Cavidade Pulpar/diagnóstico por imagem , Dentina/diagnóstico por imagem , Desenho de Equipamento , Humanos , Microtomografia por Raio-X
19.
Int J Dent ; 2021: 6697988, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33574844

RESUMO

PURPOSE: To evaluate the influence of ultrasonic activation on the physicochemical properties of setting time (ST), flow (FL), dimensional change (DC), and solubility (SL) of the cements: MTA, MTA Repair HP, and Biodentine®. MATERIALS AND METHODS: Two experimental groups were formed according to the cement activation protocol: without ultrasonic activation and with ultrasonic activation. Cements were manipulated according to the manufacturers' instructions. Ultrasonic activation group was performed with an E1 insert at power 3 (24-32 kHz) for 30 s directly in the center of the cement mass. The molds for analysis of the physicochemical properties were filled out and evaluated according to specification No. 57 from ANSI/ADA. The results were analyzed using the ANOVA test (two-way), complemented by Tukey's test (α = 0.05). The distilled water used during the solubility test was submitted to spectrometry to verify the release of calcium ions. The morphologies of the external surface and the cross-section of the samples were analyzed by means of a scanning electron microscope (SEM). RESULTS: For the ST, ultrasonic activation reduced the values of MTA, MTA Repair HP, and Biodentine (P < 0.05). For the FL, ultrasonic activation did not alter the flow of MTA (P > 0.05); however, it increased the flow MTA Repair HP and Biodentine (P < 0.05). For the DC, the percentage values of dimensional change were higher when there was ultrasonic activation in all repair cements (P < 0.05). For SL, there was a reduction in the percentage of the values in MTA and MTA Repair HP (P < 0.05); however, there was no change in the values of Biodentine (P > 0.05). Ultrasonic activation favored the release of calcium ions from all cements. The SEM analysis showed, in general, that the ultrasonic activation reduced and altered the particle shape of the cement. CONCLUSIONS: The ultrasonic activation interfered in the ST, DC, FL, ultrastructural morphology, and calcium release of the repair cements. However, it did not affect the solubility of Biodentine®.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...